FREQTRACKMODE=DISABLED, TIMGEAR=GEAR0
No Description
FREQTRACKMODE | Frequency tracking mode 0 (DISABLED): Frequency tracking disabled. Only a one-time frequency offset compensation applied through DSA. 1 (MODE1): Frequency tracking enabled with one correction, when needed, every 16 symbol periods. 2 (MODE2): Frequency tracking enabled with one correction, when needed, every 32 symbol periods. 3 (MODE3): Frequency tracking enabled with one correction, when needed, every 48 symbol periods. |
TIMTRACKTHD | Timing tracking threshold |
TIMEACQUTHD | Time acquisition threshold |
TIMCHK | Time check |
TIMEOUTMODE | Timeout mode |
TIMGEAR | Timing Gear 0 (GEAR0): Execute timing tracking regardless of difference between Early/Late and Current correlation values. Referred to as fast gear. Same as GEAR3 1 (GEAR1): Execute timing tracking only when correlation value of Early/Late is 75% or less of the Current correlation value. Referred to as medium gear. 2 (GEAR2): Execute timing tracking only when correlation value of Early/Late is 50% or less of the Current correlation value. Referred to as slow gear. |
FREQBIAS | Frequency estimation bias |
HIPWRTHD | High Power detection threshold |
SYNCTIMEOUTSEL | SYNC-WORD DET TIMEOUT |